Goodman AC & Heat Pump Error Codes: Full List & Meanings
Every Goodman ac & heat pump error code in the Goodman GSXC7 installation instructions, unitary diagnostic codes, as published by Alpine Home Air (manual copy), with its meaning. This list covers gsxc7 variable-speed air conditioners (7-segment diagnostic display). Codes vary by model, so confirm in your owner's manual. Support: Goodman dealer or Goodman customer support (goodmanmfg.com).
Codes by system
Venting / airflow
Power supply
All Goodman ac & heat pump error codes
Codes marked "Reset only" or "Service" have no separate page because the manufacturer publishes no owner fix beyond a reset or a service call.
| Code | Meaning | System | Owner action |
|---|---|---|---|
| A2 | Outdoor air temperature sensor fault: the sensor is shorted, open, disconnected or out of range. | Sensors | Service |
| A3 | Outdoor coil temperature sensor fault: the sensor is shorted, open, disconnected or out of range. A heat pump may fail to heat. | Sensors | Service |
| E5 | Open fuse: a short in the low-voltage wiring has blown the control's fuse, and the system fails to operate. | Power supply | Service |
| EE | Internal fault: board mis-operation; the manual lists welded compressor relay contacts as the cause. | Control / electronics | Service |
| b0 | The indoor circulator blower motor is not running when it should be (communicating ComfortBridge systems). | Motor / drive | Service |
| b9 | Low indoor airflow: airflow is lower than demanded, so the system runs at reduced performance or stays on low stage. Listed causes include an indoor blower problem, blocked filters, restrictive or undersized ductwork, or mismatched indoor and outdoor units. | Venting / airflow | Owner checks |
| d0 | Data not yet on the communicating network (ComfortBridge). | Control / electronics | Service |
| d1 | Invalid data on the communicating network. | Control / electronics | Service |
| d2 | System mismatch: the outdoor unit requires more airflow than the indoor unit can deliver, or shared data is incompatible or missing. | Control / electronics | Service |
| d3 | Configuration error with the shared data sent to the control. | Control / electronics | Service |
| d4 | Invalid memory card data. | Control / electronics | Service |
| 01 | Low side fault or low pressure switch open. Listed causes: low refrigerant charge, a liquid-line restriction, an indoor blower motor failure or the thermostat set extremely low. Shown as L1 when the control locks out. Also: L1 | Heating | Service |
| 02 | High side fault or high pressure switch open. Listed causes: a blocked condenser (outdoor) coil or the outdoor fan not running. Shown as L2 when the control locks out. Also: L2 | Venting / airflow | Owner checks |
| 03 | Short cycling: run time for the last four cycles was too short. Listed causes: intermittent thermostat demand or a faulty compressor relay. | Control / electronics | Service |
| 04 | Locked rotor: the compressor did not start. Listed causes: seized compressor bearings, a failed run capacitor or its wiring, or low line voltage. | Motor / drive | Service |
| 05 | Open circuit: power is disconnected, the compressor protector has failed, or the compressor is not wired properly to the control. | Power supply | Owner checks |
| 06 | Open start circuit: the compressor start winding is open, the run capacitor or its wiring has failed, or the compressor is miswired. Shown as L6 when locked out. Also: L6 | Motor / drive | Service |
| 07 | Open run circuit in the compressor. Shown as L7 when locked out. Also: L7 | Motor / drive | Service |
| L8 | Low line voltage: the control detects supply voltage below the rating-plate range. | Power supply | Owner checks |
| H8 | High line voltage: the control detects supply voltage above the rating-plate range. | Power supply | Service |
Symptoms
Sources
- Alpine Home Air (manual copy): Goodman GSXC7 installation instructions, unitary diagnostic codes (third-party copy of manufacturer service data)