Kenmore Gas water heater Error Codes: Full List & Meanings
Every Kenmore gas water heater error code in the Kenmore gas water heater error-code chart, as published by Sears PartsDirect, with its meaning. Codes vary by model, so confirm in your owner's manual. Support: Kenmore customer support (kenmore.com) or a Sears-authorized technician.
Smell gas? Leave the building now. Do not touch light switches, phones or appliances inside. Call your gas utility or 911 from outside. CO alarm sounding or headache, dizziness or nausea? Get everyone outside and call 911. Gas valves, burners, venting and wiring are for a licensed technician only. See our safety policy.
Codes by system
Sensors
Heating
All Kenmore gas water heater error codes
Codes marked "Reset only" or "Service" have no separate page because the manufacturer publishes no owner fix beyond a reset or a service call.
| Code | Meaning | System | Owner action |
|---|---|---|---|
| LED Flashes once every 4 seconds | Water heater is at idle (no call for heat, no fault condition). | Heating | Service |
| LED alternates bright/dim | Water heater is heating (no fault condition). | Heating | Service |
| LED Flashes once every 3 seconds | Low flame signal. | Heating | Service |
| LED Flashes 2 times every 3 seconds | Air pressure switch closed. | Sensors | Reset only |
| LED Flashes 3 times every 3 seconds | Air pressure switch open. A long vent or blocked vent can prevent the pressure switch from closing when blower is running. | Sensors | Reset only |
| LED Flashes 4 times every 3 seconds | Exceeded temperature limit. | Heating | Service |
| LED Flashes 5 times every 3 seconds | Flame out. | Heating | Service |
| 6-1 | Ignition failure. The gas control failed to ignite the burner and has gone into locked-out state. | Heating | Service |
| 6-2 | Pressure switch/high limit opened. The gas control has sensed a repeated failure in the vent protection switches. | Sensors | Owner checks |
| 6-3 | Flame lost. The gas control sensed a repeated failure in the flame sensing circuitry during operation and has shut down the water heater. | Heating | Service |
| 6-4 | Flame out of sequence sensed. The gas control sensed a malfunction in the sequence of operation and has shut down the water heater. | Heating | Owner checks |
| 7 LED Flashes every 3 seconds | Flammable vapor sensor (FVS). The gas control has sensed a problem with the flammable vapor sensor. | Sensors | Service |
| 8-1 | Flammable Vapor Sensor (FVS). The gas control has sensed a problem with the flammable vapor sensor. | Sensors | Service |
| 8-2 | Temperature sensor fault. | Heating | Owner checks |
| 8-3 | Gas control failure. | Heating | Owner checks |
| 8-4 | Gas control failure. | Heating | Owner checks |
| LED is constantly on | Gas control failure. | Heating | Reset only |
Symptoms
Sources
- Sears PartsDirect: Kenmore gas water heater error-code chart (third-party copy of manufacturer service data)
Last reviewed: October 20, 2026. ErrorCodePro is not affiliated with Kenmore.