Lennox Furnace Error Code E223: Meaning & How to Fix It

By the ErrorCodePro Editorial Team · Last reviewed October 20, 2026

Lennox furnace error code E223 means: The low pressure switch didn't close. Lennox inspects the vent and combustion air inducer for restriction. [1] Keep using it? No. Don't keep resetting it. If it locks out again, call a technician.. Start with the owner checks below, beginning with: clear the vent terminals.

Smell gas? Leave the building now. Do not touch light switches, phones or appliances inside. Call your gas utility or 911 from outside. CO alarm sounding or headache, dizziness or nausea? Get everyone outside and call 911. Gas valves, burners, venting and wiring are for a licensed technician only. See our safety policy.

Quick facts

CodeE223
Also shown asE227
Brand / applianceLennox furnace (sl280dfv surelight gas furnaces (service literature 1117-l4))
SystemVenting / airflow
Official meaningThe low pressure switch didn't close. Lennox inspects the vent and combustion air inducer for restriction. [1]
Keep using it?No. Don't keep resetting it. If it locks out again, call a technician.
DIY-safe?Owner checks only (listed below)
SupportLennox dealer (lennox.com)

On this page: Meaning · Steps · Parts · When to call a technician · Related codes · FAQ

What error code E223 means on an Lennox furnace

The low pressure switch didn't close. Lennox inspects the vent and combustion air inducer for restriction. [1]

This is a venting / airflow code. Codes and wording can vary by model, so check your owner's manual for your model number.

How to fix Lennox furnace error code E223 (safe owner checks)

Owner checks only: on heating, cooling and water-heating equipment, limit yourself to reading the code and checking the thermostat, breaker and service switch, air filter, condensate drain, that the gas supply valve is open (no disassembly) and that vent terminals are clear of snow or debris. Reset power only if your manual allows it.
Safety first: disconnect power before you remove any panel or reach into the sump or drum. Do not touch wiring, the control board or the motor. If you see water near electrical parts, stop and call a technician. These steps are based on Lennox's published guidance [1], rewritten for clarity.
  1. Clear the vent terminals. Outside, make sure the exhaust and intake pipes are free of snow, ice, leaves or nests. Don't take anything apart.
  2. Check the condensate drain. On high-efficiency (condensing) furnaces, make sure the condensate line and trap aren't visibly blocked, frozen or backed up.

Parts that may be involved

Exact parts depend on your model number. This page lists part types only, never part numbers.

No specific part is implied by the manufacturer's guidance for this code.

When to call a technician

Frequently asked questions

What does error code E223 mean on an Lennox furnace?

Lennox lists E223 as follows: The low pressure switch didn't close. Lennox inspects the vent and combustion air inducer for restriction.

Is it safe to keep using the furnace with E223?

No. Don't keep resetting it. If it locks out again, call a technician..

Can I fix Lennox furnace error E223 myself?

Only with the owner checks on this page, starting with: clear the vent terminals. If it persists, call a technician or Lennox dealer (lennox.com).

Is E227 the same as E223?

Yes. Lennox's documentation lists E227 with the same meaning as E223; the display format depends on the model.