Samsung RS30 and RSG307 models side-by-side refrigerator Error Codes: Full List & Meanings
Every Samsung RS30 and RSG307 models side-by-side refrigerator error code in the Samsung RS30 and RSG307 models side-by-side refrigerator error-code chart, as published by Sears PartsDirect, with its meaning. Codes vary by model, so confirm in your owner's manual. Support: Samsung Support Center (samsung.com/us/support).
Codes by system
Heating
Venting / airflow
All Samsung RS30 and RSG307 models side-by-side refrigerator error codes
Codes marked "Reset only" or "Service" have no separate page because the manufacturer publishes no owner fix beyond a reset or a service call.
| Code | Meaning | System | Owner action |
|---|---|---|---|
| 1 E | Freezer temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature), 13,290 ohms at 32 degrees and 29,000 ohms at 0 degrees. The meter should read the same resistance as for the temperature sensor. | Heating | Service |
| 2 E | Refrigerator compartment temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature), 13,290 ohms at 32 degrees and 11,700 ohms at 37 degrees. The meter should read the same resistance as for the temperature sensor. | Heating | Service |
| 4 E | Freezer evaporator defrost temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature), 13,290 ohms at 32 degrees and 29,000 ohms at 0 degrees. The meter should read the same resistance as for the temperature sensor. | Heating | Service |
| 5 E | Refrigerator evaporator defrost temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature) and 13,290 ohms at 32 degrees. The meter should read the same resistance as for the temperature sensor. | Heating | Service |
| 6 E | Ambient temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature). The meter should read the same resistance as for the temperature sensor. | Heating | Service |
| 8 E | Ice maker temperature sensor failure. The meter should measure about 5,600 ohms if the sensor temperature is 72 degrees (room temperature), 13,290 ohms at 32 degrees and 29,000 ohms at 0 degrees. | Heating | Owner checks |
| 13 E | Humidity sensor failure. The meter should measure around 50 ohms of resistance. | Sensors | Service |
| 21 E | Freezer evaporator fan failure. | Venting / airflow | See page |
| 22 E | Refrigerator evaporator fan failure. | Venting / airflow | See page |
| 23 E | Condenser fan failure. | Venting / airflow | Owner checks |
| 24 E | Freezer evaporator defrost system failure. The meter should measure about 63 ohms of resistance. The meter should measure about 63 ohms through the defrost heater. | Heating | Service |
| 25 E | Refrigerator evaporator defrost system failure. The meter should measure about 120 ohms of resistance. The meter should measure about 120 ohms through the defrost heater. | Heating | Service |
| 26 E | Ice maker failure. | Dispenser | See page |
| 27 E | Pantry drawer air damper heater failure. The air damper heater wires are included in the air damper motor wire harness. The meter should measure about 135 ohms through the air damper heater. | Heating | Reset only |
| 33 E | Ice maker fill tube heater failure. The yellow and pink wires connect to the ice maker fill tube heater. The meter should measure around 102 ohms. | Water fill | Service |
| 41 E | Communication error between the control panel and electronic control board. Also: Pc Er | Control / electronics | Service |
| 81 E | Compressor failed to start. The technician will need to conduct live voltage checks to determine the cause of the problem. | Control / electronics | Service |
| 82 E | Inverter board failure. | Control / electronics | Service |
| 83 E | Compressor is drawing abnormal current. The technician will need to conduct live voltage and current checks to determine the cause of the problem. | Control / electronics | Service |
| 84 E | Compressor locked. | Control / electronics | Service |
| 85 E | Voltage supply to the compressor is too low. The technician will need to conduct live voltage checks to determine the cause of the problem. | Power supply | Service |
| 86 E | Voltage supply to the compressor is too high. The technician will need to conduct live voltage checks to determine the cause of the problem. The freezer temperature display shows the number designation of the code and the refrigerator temperature display shows E.","nodeType":"text"}],"nodeType":"paragraph"},{"data":{},"content":[{"data":{},"marks":[],"value":"When the control detects a communication error between the control panel and the electronic control board, the freezer temperature display shows Er and the refrigerator display shows Pc.","nodeType":"text"}],"nodeType":"paragraph"},{"data":{},"content":[{"data":{},"marks":[],"value":"Refer to the chart below to find the cause of the error code and get troubleshooting advice to clear the code.","nodeType":"text"}],"nodeType":"paragraph"},{"data":{},"content":[{"data":{},"marks":[],"value":"The refrigerator may work properly even though the control displays an error code. | Power supply | Reset only |
Symptoms
Sources
- Sears PartsDirect: Samsung RS30 and RSG307 models side-by-side refrigerator error-code chart (third-party copy of manufacturer service data)
Last reviewed: October 20, 2026. ErrorCodePro is not affiliated with Samsung.